BYCYW - ZEP FOCUS #0812 (FLOOR FINISH)
- MSDS: BYCYW
- Manufacturer: ZEP MFG CO DIV OF NATIONAL SERVICE INDUSTRIES
- Product Name: ZEP FOCUS #0812 (FLOOR FINISH)
- National Stock Number: 7930-01-412-2388
Product Identification
Product ID:ZEP FOCUS #0812 (FLOOR FINISH)
MSDS Date:06/01/1992
FSC:7930
NIIN:01-412-2388
MSDS Number: BYCYW
Responsible Party
ATLANTA, GA 30301
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 404-352-1680 DAYS/404-435-2973 OTHR
Cage: 27674
Contractor
Telephone: 877-428-9937
Cage: 27674
Ingredients
2-(2-ETHOXYETHOXY)-ETHANOL (SARA 313) (DIETHYLENE GLYCOL
CAS: 111-90-0
RTECS: KK8750000
Fraction By Weight: <5%
DIPROPYLENE GLYCOL METHYL ETHER (DIPROPYLENE GLYCOL
CAS: 34590-94-8
RTECS: JM1575000
Fraction By Weight: <5%
OSHA PEL 100 PPM/STEL 150 PPM
ACGIH TLV: 100 PPM/STEL 150 PPM
2,2,4-TRINETHYL-1,3-PENTADIOL MONOISOBUTYRATE
CAS: 25265-77-4
RTECS: UF6000000
Fraction By Weight: <5%
Hazards
LD50 LC50 Mixture:NOT EST.
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY IRRIT EYES/SKIN. EYE INFLAM
- REDNESS, ATERING, TCHING. SKIN INFLAM - ITCHING, SCALING,
REDDENING, SOMETIMES BLISTERING. INHAL: OVEREXPOS MAY CAUSE CNS
DEPRESSION - NAUSEA/VOMITING. CHRONIC : REPEATED/PROLONGED SKIN
CONTACT MAY PRODUCE CHRONIC INFLAMMATION OR DERMATITIS - REDNESS,
SCALING OR ITCHING.
Explanation of Carcinogenicity:NONE OF THE INGREDIENTS ARE LISTED AS
CARCINOGENS BY IARC, NTP, OSHA.
Medical Cond Aggravated by Exposure:OVEREXPOSURE BY INHALATION OR SKIN
ABSORPTION MAY PRODUCE MILD CENTRAL NERVOUS SYSTEM DEPRESSION
CHARACTERIZED BY HEADACHE, DIZZINESS, NAUSEA, VOMITING.
First Aid
First Aid:SKIN: IMMEDIATELY FLUSH CONTAMINATED SKIN W/PLENTY WATER AT
LEAST 15 MINUTES. GET MED AID IF IRRITATION DEVELOPS. EYES: IMMED
FLUSH W/PLENTY WATER AT LEAST 15 MINUTES, OCCASIONALLY LIFTING
LIDS. GET M EDICAL AID AT ONCE. INHAL: GET FRESH AIR. IF IRRITATION
PERSISTS GET MEDICAL AID PROMPTLY. INGESTION: DON'T INDUCE
VOMITING. IF VICTIM CONSCIOUS GIVE PLENTY WATER TO DRINK. GET
MEDICAL AID AT ONCE.
Fire Fighting
Flash Point:NONE
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NONCOMBUSTIBLE
Fire Fighting Procedures:POSITIVE PRESSURE SCBA.
Unusual Fire/Explosion Hazard:FIRE-EXPOSED DRUMS SHOULD BE COOLED
W/STREAM OF WATER.
Accidental Release
Spill Release Procedures:ABSORB ON INERT ABSORBENT MAT'L (E.G.
ZEP-O-ZORB). PICK UP/PLACE RESIDUE IN SUITABLE WASTE CONTAINER OR
IF PERMITTED, FLUSH TO SEWER. THOROUGHLY RINSE SPILL AREA W/WATER.
OBSERVE HANDLING/STORAGE/PROT ECTIVE MEASURES AS LISTED BELOW.
Handling
Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED IN DRY
AREA. STORE 40-120F. KEEP AWAY FROM SKIN/EYES & FOOD/FOOD
PRODUCTS.
Other Precautions:CLOTHING/SHOES THAT BECOME CONTAMINATED W/SUBSTANCE
SHOULD BE REMOVED PROMPTLY, NOT REWORN UNTIL THOROUGHLY CLEANED.
KEEP AWAY FROM CHILDREN.
Exposure Controls
Respiratory Protection:NO EXTRA MEASURES NEEDED IF VENTILATION
ADEQUATE.
Ventilation:PROVIDE LOCAL EXHAUST/VENT AS NEEDED TO KEEP VAPOR
CONCENTRATIONS
Eye Protection:**
Supplemental Safety and Health
*NATURAL RUBBER, NEOPRENE, NITRILE GLOVES RECOMMENDED IF PROLONGED SKIN
CONTACT EXPECTED. **TIGHT-FITTING SAFETY GLASSES RECOMMENDED IF
SPLASHING MAY OCCUR.
Chemical Properties
Boiling Pt:B.P. Text:215F,102C
Vapor Pres:= TO WATER
Spec Gravity:1.02
pH:*
Evaporation Rate & Reference:<1 (WATER=1)
Solubility in Water:COMPLETE
Appearance and Odor:OPAQUE, MILKY-WHITE LIQUID, MILD AMMONIA ODOR *PH
CONCENTRATE = 8.0-8.5.
Percent Volatiles by Volume:80
Stability
Stability Indicator/Materials to Avoid:YES
HEAT, SUNLIGHT, STRONG OXIDIZERS, ACID.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE, OTHER
UNIDENTIFIED ORGANIC COMPOUNDS.
Disposal
Waste Disposal Methods:LIQUID WASTES NOT PERMITTED IN LANDFILL. PRODUCT
NOT HAZ WASTE (RCRA). ABSORB UNUSABLE LIQ ON INERT ABSORBENT, DRUM,
TAKE TO CHEM/INDUSTRIAL LANDFILL. IN SOME AREAS OK TO FLUSH TO
SANITARY SEWER W/WAT ER. SEE APPLICABLE LAWS FOR PROPER DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.